Fantech HRV/ERV Systems
Please call 1-800-949-OBAR for pricing and availability.
Please call 1-800-949-OBAR for pricing and availability.
Our modular design allows replacement of the interior motor assembly without needing to replace the outer enclosure.
Operating Range : 108 – 132 Volts AC RMS, 50/60 Hz, Single Phase
Max. Static Pressure: 16″ w.c. @ 0 CFM
Max. Airflow : 155 CFM @ 0″ w.c.
Built in speed control to customize performance.
Built in condensate bypass.
* GBR76 SOE and UD can be interchanged as long as correct voltage is being supplied. Refer to operating ranges.
Modular design allows replacement of the inner motor assembly without needing to replace the outer enclosure.
Operating Range : 100-240 Volts AC RMS, 50/60 Hz, Single Phase
Max. Static Pressure : 37″ w.c. @ 0 CFM
Max. Airflow : 195 CFM @ 0″ w.c.
Built in speed control to customize performance.
Built in condensate bypass.
* GBR76 SOE and UD can be interchanged as long as correct voltage is being supplied. Refer to operating ranges.
Modular design allows inner motor assembly to be replaced without the need to replace the outer enclosure.
Operating Range 240V: 216 – 264 Volts AC RMS, 50/60 Hz, Single Phase
Operating Range 120V: 108 – 132 Volts AC RMS, 50/60Hz, Single Phase
Max. Static Pressure : 14″ w.c. @ 100 CFM
Max Airflow : 545 CFM @ 0″ w.c.
Built in speed control to customize performance.
Built in condensate bypass.
.08 – 1.2″ w.c. pressure sensor.
Built-in audible and visual alarm.
Field adjustable alarm set-point.
4 options for actuation delay and 4 options for silence duration.
Includes 2XAAA batteries, system label and length of vacuum tube.
.08 – 1.2″ w.c. pressure sensor.
Built-in audible and visual alarm.
Field adjustable alarm set-point.
Includes power adapter, system label and 2′ of vacuum tube.
0-4″ Digital Differential Pressure Gauge
Built-in audible and visual alarm with push to silence feature.
Fully programmable for alarm set-point, delay (display and alarm), units and more.
Pipe or wall mountable.
Includes mounting bracket/hardware, batteries, system label, 2′ of vacuum tube.
Requires 4 x AA batteries (included)
0-3″ w.c. range works with the majority of radon installations.
Outdoor rated enclosure.
Simple installation and setup.
Weather resistant system labels included.
2′ of tubing for connection to system pipe.
Sturdy, lightweight aluminum construction.
Quick, easy assembly saves time over building Unistrut mounts.
Designed for use with our GBR76 SOE, GBR76 UD and GBR89 HA Blowers.
Hardware included.
Sturdy, lightweight aluminum frame.
Provides up to 8″ of additional offset versus a direct wall mount.
Articulating design allows arm adjustment to conform to your installation needs.
Designed for use with our GBR76 SOE, GBR76 UD and GBR89 HA*.
Hardware included.
Differential Pressure Transmitter
Selectable ranges (0-1″, 0-2″ or 0-4″ w.c.)
4-20 mA or 0-10V Output Options
Wall mountable
Vapor Intrusion and Radon System Alarm and Gauge
Measures pressures up to 40″ w.c.
Audible and visual alarm with adjustable set point
Plug and play operation*
Built-in alarm silence switch
Includes power supply and length of vacuum tubing for connection to riser pipe
Includes wiring for a second programmable relay